Building envelope solutions: coating first. Stop heat before it enters the building.

The envelope is a building’s first line of performance, and the solar heat-control coating is its first layer. BECORP coats roofs and external walls to reflect part of the sun’s energy, then adds cellulose insulation and glazing film as one system.

Three layers, one envelope, starting with the coating.

Heat gets in through the roof, walls and glass. The coating works on the outer surface before heat is absorbed, the insulation slows what gets through, and the film controls the glazing.

01

Envelope Assessment

Roof, wall and glazing exposure is surveyed to see which heat-entry paths matter most.

02

Layer 1: Solar Heat-Control Coating

Applied as a liquid to metal, concrete or clay roofs and external walls, reflecting part of the solar energy and limiting surface heat absorption.

03

Layer 2: Cellulose Fibre Insulation

Reduces heat transfer through roofs, ceilings, walls and cavities, and fills irregular voids.

04

Layer 3: Glazing Solar-Control Film

Applied to existing glazing to manage solar heat, daylight, glare and privacy.

05

Detailing & Interfaces

Thermal bridges and the junctions between layers are specified together, so the system performs as one assembly.

06

Installation & Handover

Work follows the approved drawings, with materials checked against the specification at delivery.

The coating is tested, not just described.

Tested in accordance with ASTM standards C1549, C1371, E1980 and D3960. Final performance depends on certified system data, detailing and installation quality.

82.8% Solar Reflectance

Reflects part of the incident solar energy before it is absorbed.

0.87 Thermal Emittance

How readily the coated surface releases the heat it has absorbed.

SRI 102.92

The average Solar Reflectance Index, a combined measure of reflectance and emittance.

Nil VOC Result

An exterior liquid coating with a nil VOC result in testing.

From assessment to verification.

Performance is designed, installed and evidenced rather than assumed.

01

Assess

Survey roof, wall and glazing exposure against the project objectives.

02

Audit

Coordinate the appropriate energy assessment where required.

03

Identify

Locate the heat-entry paths: roof, walls, glass and thermal bridges.

04

Design

Specify coating, insulation and film as one system, with the evidence plan.

05

Execute

Supply and apply each layer to the approved drawings.

06

Verify

Measure surface temperatures and energy use against the baseline.

Scroll for more steps →

The envelope comes first.

A well-designed envelope can reduce unwanted heat gain and cooling demand as part of an integrated strategy. BECORP reduces avoidable demand first, then sizes supply to the actual need.

The right sequence is project-specific, and insulation and solar generation can work together.

Two professionals reviewing a building floor plan on a laptop in front of a glass facade

Roof temperature readings taken on real jobs.

FIELD READING

Roof coating, before and after

The same infrared thermometer, the same uncoated metal roof, before and after the coating went on: 66.6°C on 11 March at 11.02am, and 35.1°C on 11 May at 11.48am. These photos come from BECORP’s own jobs.

Coating

Solar direct reflectance

82.8%
0.87 thermal emittance, average SRI 102.92
Insulation

R-value at 50 mm

R-7.4
R-3.4 at 25 mm, 0.0384 W/m·K
Energy

Industrial buildings

Up to 30%
Depends on insulation, materials and site

Documentation is part of delivery.

Certified System Data

Final performance depends on certified system data, detailing and installation quality.

GBI Submission Support

Envelope performance data is prepared in the form green-building assessors expect.

Performance Verification

Where applicable, outcomes can be measured against an agreed baseline and documented method.

Labour & Materials Warranty

BECORP provides labour and materials warranty according to the applicable project contract and product documentation.

Is heat getting in through your roof, walls or glass?

Start with the surfaces taking the sun, and the performance you need to achieve.

Talk to BECORP about a coating, insulation and film system specified as one envelope.